The Basics: Azimuth and Tilt
Two angles define how your panels interact with the sun:
- Azimuth: the compass direction the panels face. South = 0°, East = -90°, West = +90°.
- Tilt: the angle of the panels relative to horizontal. A flat roof = 0°; a steep Swiss chalet roof might be 45–55°.
In Switzerland (latitude approximately 46–48°N), the theoretical optimum for maximum annual yield on a south-facing surface is a tilt of 30–35 degrees. Deviating from this costs yield — but often less than homeowners expect.
How Much Does Orientation Cost in Yield?
Using Meteonorm climate data for Zurich (representative of the Swiss plateau), a south-facing 7 kWp system at 35° produces approximately 6,500 kWh/year. Here is how other orientations compare:
| Orientation | Tilt | Relative yield (vs south 35°) |
|---|---|---|
| South | 35° | 100% |
| South | 20° | 96–97% |
| South-East / South-West | 35° | 93–95% |
| East-West split | 30° each | 88–92% |
| East or West only | 35° | 78–83% |
| Flat (0°) | 0° | 82–85% |
| North-facing | 35° | 55–65% |
These figures are approximations — actual numbers depend on local horizon shading, cloud patterns, and altitude.
→ Still unsure if the maths add up? Check your personal payback period — it takes 60 seconds.
The East-West Split Argument
Many Swiss roofs are oriented east-west rather than south-north, making an east-west split installation the only option. While total annual yield is 8–12% lower than a pure south installation, the production profile is often more useful:
- Morning peak from the east array coincides with breakfast electricity use
- Evening peak from the west array coincides with cooking, EV charging, and evening appliance use
- Flatter daily curve means less midday excess that must be exported at low feed-in rates
- Self-consumption rate is typically 5–10 percentage points higher on an east-west split than on a south system of equal size — important in Switzerland where the feed-in remuneration (Rückspeisevergütung) is just CHF 0.07–0.12/kWh
For homes with an EV or heat pump, the flatter production curve of an east-west split frequently outperforms a south array in net financial terms, even with lower gross yield.
Flat Roofs: Optimal Tilt for Switzerland
Flat-roof systems use mounting structures to set the tilt. The trade-offs:
- Tilt 10–15°: minimal shading between rows, allows dense packing but reduces yield by 12–15% vs optimal
- Tilt 20–25°: good self-cleaning (rain washes debris and snow off more effectively), better yield, requires more row spacing
- Tilt 30–35°: optimal annual yield but significantly more row spacing needed — typically only worthwhile if roof area is not the constraint
For flat-roof ZEV installations on Swiss apartment buildings, 15–20° is most common — a practical compromise between yield and packing density.
Alpine Considerations
Above approximately 800m elevation, several factors modify the standard calculation:
- Higher irradiance: UV radiation increases roughly 8–10% per 1,000m altitude, boosting panel output on clear days
- Snow albedo: light reflecting off snow can increase incident radiation on low-tilt panels by 10–20% in winter months, making steeper tilts more attractive for pure south installations
- Snow shedding: panels tilted below 20° are at higher risk of snow accumulation. At alpine altitudes, a 35–40° tilt is often recommended for passive snow shedding — reducing winter yield loss
- Temperature advantage: alpine air temperatures are lower, which improves panel efficiency (crystalline silicon panels lose ~0.35% efficiency per degree Celsius above 25°C STC)
- Longer shading periods: surrounding mountains cause morning and evening shading that south-only systems in valleys experience significantly
Bifacial Panels and Flat Roofs
Bifacial panels (models from Meyer Burger, 3S Swiss Solar, and others) can capture reflected light from a pale or reflective flat roof surface. In Switzerland, bifacial gain on flat roofs is typically 5–12% — most valuable at altitude or on white membrane roofs that maximise albedo.